LDJ-5

The CHARGE INJECTOR LDJ-5 was developed especially with respect to on-site PD diagnosis tests, using the DIFFERENTIAL LEMKE PROBE LDP-5.

Applications

  • Delivers higher charge magnitudes
  • Generation of PD-pulse charges up to 10,000pC
  • The main purpose is the simulation f heavy PD activities, which may be typical for large generators, transformers and cable sealing ends. For this purpose 3 BNC-jacks with calibrating charge of 500, 2,000, and 10,000 pC are available
  • Classical calibrator according to IEC 60270
  • The injector can also be used as charge radiator

Specifications

  • Rated pulse charges: 500 - 2,000 - 10,000
  • Calibration capacitor: 100 pF, approx.
  • Battery-powered

Downloads

  • Data Sheet LDJ-5