PD-Smart

Digital, highly advanced, multi-purpose and smart Partial Discharge and Diagnostics System.

Applications

Digital, highly advanced, multi-purpose and smart Partial Discharge and Diagnostics System for on-line and off-line PD testing on power apparatus and high voltage insulation systems, for both in-house and on-site applications. Allows multichannel, synchronous Partial Discharge Measurements e.g. on transformers

  • according to the standard IEC 60270, VDE 0434, ANSI as well as various IEEE standards
  • PD quality tests on high voltage equipment
  • PD diagnosis on developing insulating materials
  • Designed for on-site PD diagnosis tests as well as for manufacturing and research
  • PD fault location for power cables

User Benefits

  • single or multi-channel (scaleable)
  • truly parallel and synchronous measurement of phi-Q-N pattern
  • remote controlled via LAN and PC
  • Advanced LDIC Noise-Gating-Technology:
    with integrated noise-gating channel for noise-suppression viaexternal antenna
  • easy suppression of phase-locked noise by an unlimited number of Windows
  • small compact design for stationary or on site use
  • integrated battery
  • features the well known LDIC Analysis and Diagnostics software
  • expandable for various PD / RIV applications up to tan δ / Power Factor

Specifications

PD detection:

  • permanent detection of all PD events
  • digital, numeric real-time integration of PD events
  • integration in time and frequency range
    • time range: 100 ns .... 10 µs
    • frequency range: center frequency: 0 Hz .... 20 MHz
    • band width: 9 kHz, 30 kHz, 100 kHz, 300 kHz, 1 MHz, 3 MHz
  • charge evaluation full compatible to IEC 60270, VDE 0434, ANSI
  • single pulse detection: < 3 ns
  • max. double pulse resolution: <200ns (time range, superpositionerror < 1 %)
  • max. pulse frequency: 2 MHz
  • Input frequency range:
    • Voltage: DC to 10 kHz
    • PD signal: DC to 20 MHz
  • Input impedance:
    • Voltage: 1 MOhm
    • PD signal: 50 Ohm
  • Input voltage:
    • Voltage: 50 V rms (max)
    • PD signal: 10 V rms (max)
  • Dynamic range:
    • Voltage:16 bit, 80 dB
    • PD signal:16 bit, 100 dB
  • PD input protection:
    • input protection against over-voltage and short-circuit
  • PD input coupling:
    • DC, AC
  • Voltage supply:
    • 8,4 V DC with battery
    • external power supply(100 - 240 V, 50 - 60 Hz)
  • Outputs:
    • 1 x LWL-Output with E/O converteras electrical Ethernet
  • Inputs:
    • 2 x TNC (HF PD signal, NF voltage signal),
    • 1 x TTL signal for gating
  • Temperature range:
    • 0 °C to40 °C (operation)
    • 0 °C to 60°C (storage)
  • Humidity:
    • 5 % to 95 %, non-condense

Downloads

  • Prospect PD Smart